Linkedin Labtau  

Publications

Last updated 19 August 2024

Displaying 6126 - 6150 of 7089
  • Simultaneous monitoring of non invasive hemodynamic profile and capnography for tissue perfusion evaluation
    Tournadre JP, Moulaire V, Barreiro G, Brunel D, Van Straten V, Muchada R
    J Anesth, 8 , 400- 405, 1994
  • Utilisation d'une émulsion de fluorocarbure pour la conservation en normothermie de blocs multi-viscéraux chez le rat : Etude préliminaire
    Voiglio EJ, Gorry F, Zarif L, Margonari J, Cloix P, Martin X, Riess J, Dubernard JM
    Lyon Chir, 6 , 446- 450, 1994
  • High intensity focused ultrasound vs hepatectomy for VX-2 carcinoma in the rabbit: preliminary results of an experimental randomized study
    Prat F, Centarti L, Henry L, Sibille A, Chapelon JY, Cathignol D
    - Oslo -
    1994
  • Alterazioni emodinamiechi e variazioni della pressione tele-espiratoria di CO2 (Pet CO2) nelle anestesie per colecistectomia per via laparoscopica
    Rinaldi A, Muchada R
    - Rome -
    1994
  • Non-invasive measurement of direct and reflected pulse waves in human lower limbs
    Risacher F, Jossinet J, Schmitt M
    - Baltimore - USA
    1994
  • Etude atraumatique de la propagation de l'onde de pouls au niveau des membres inférieurs chez l'homme
    Risacher F, Jossinet J, Schmitt M
    - -
    1994
  • Rat multiple organ blocks perfused with perfluorooctyl bromide emulsions
    Voiglio EJ, Gorry F, Zarif L, Margonari J, Cloix P, Riess J, Dubernard JM
    - -
    1994
  • Bioelectrical spectroscopy from multi-frequency EIT
    Griffiths H, Jossinet J
    Physiol Meas, 15 , A59- A63, 1994
  • Active current electrodes for in vivo electrical impedance tomography
    Jossinet J, Tourtel C, Jarry R
    Physiol Meas, 15 , A83- A90, 1994
  • Electrode-Electrolyte Interface Impedance: Detection of the onset of linearity
    McAdams ET, Jossinet J
    IEEE Trans Biomed Eng, 41(5) , 1- 3, 1994
  • A physical interpretation of Schwan's limit voltage of linearity
    McAdams ET, Jossinet J
    Med Biol Eng Comput, 32(2) , 126- 130, 1994
  • Performance and operation of a set of wideband current generators for EIT
    Jossinet J, Tourtel G, Jarry R
    - -
    1994
  • A 2MHz wide band full wave distributed impedance tomograph
    Jossinet J, Tourtel G, Risacher F
    - Baltimore - USA
    1994
  • Neural networks for data classification in electrical impedance tomography
    Lau NJ, Jossinet J, Marques de Sá JP, Reis LP
    - Lisbonne - Portugal
    1994
  • Neural Networks for data classification in Electrical Impedance Tomography
    Lau NJ, Jossinet J, Marques de Sà JP, Reis LP
    - Lisbon - Portugal
    1994
  • AC impedance of the hydrogel-skin interface
    McAdams ET, Lackermeier A, Jossinet J
    - Baltimore - USA
    1994
  • Design and characterization of a shock wave generator using canalized electrical discharge: Application to lithotripsy
    Bourlion M, Dancer P, Lacoste F, Mestas JL, Cathignol D
    Rev Sci Instrum, 65(7) , 2356- 2363, 1994
  • On the spectral properties of Doppler thread phantoms
    CATHIGNOL D, DICKERSON K, NEWHOUSE VL, FAURE P, CHAPELON JY
    Ultrasound in Med and Biol, 20(7) , 601- 610, 1994
  • Effects of high-intensity ultrasound on malignant cells and tissues
    Gelet A, Chapelon JY
    Application of newer forms of therapeutic energy in urology , 107- 114, 1994
  • Acquisition and analysis of the impedance cardiogram (ICG) in the detection of ventricular arrhythmias
    Dempsey GJ, Imam SZ, Johnston PW, Jossinet J
    - Baltimore - USA
    1994
  • Hemodinamica y circulacion extracorporea en cirugia cardiaca
    Muchada R
    - Barcelona - Espana
    17 Septembre 1993
  • ECHOENDOSCOPY PRIOR TO ENDOSCOPIC TUMOR-THERAPY - MORE SAFETY
    SOUQUET JC, NAPOLEON B, PUJOL B, PONCHON T, KERIVEN O, LAMBERT R
    ENDOSCOPY, 25(7) , 475- 478, 1993
  • Beam steering of shock waves generated by a piezo-composite lithotriptor
    Cathignol D, Birer A, Chapelon JY
    - Baltimore - USA
    31-3 Octobre-Novembre 1993
  • The feasibility of tissue ablation using high intensity electronically focused ultrasound
    Chapelon JY, Faure P, Plantier M, Cathignol D, Souchon R, Gorry F, Gelet A
    - Baltimore - USA
    31 Octobre 1993
  • BEAM-STEERING OF SHOCK-WAVES GENERATED BY A PIEZO-COMPOSITE LITHOTRIPTOR
    CATHIGNOL D, BIRER A, CHAPELON JY
    IEEE 1993 Ultrasonics Symposium - BALTIMORE, MD -
    OCT 1993

Pages