-
Low cost field effect transistor device-comprises gate-electrode on substrate and sepd. from polymeric semiconducting layer by insulating layer
ALLEN P C, FRIEND R H, BURROUGHES J H, PHILIP C A, BURROUGHS J H, RICHARD H F
(JP1036076-A) , 1989
-
Arc discharge control for generation of shock waves-uses high resistance placed between arcing electrodes to produce undamped shock wave in liquids for medical use
CATHIGNOL D, LACRUCHE B, MESTASJL, MESTAS J L
(DE3865545-G) , 1989
-
Lithotriptic shock wave generator with truncated ellipsoidal reflector-redistributes acoustic energy density across surface of skin where little or no sensation can be felt
MESTAS J L, CATHIGNOL D, LACRUCHE B, MESTAS J
(US5233980-A) , 1989
-
Focussed ultrasonic wave generator-has gps. of piezoelectric transducers arrayed w.r.t. common focal points, with resonance frequencies in geometrical progression
CATHIGNOT D, LACRUCHE B, MESTAS J L, CATHIGNOL D
(US5015929-A) , 1989
-
Lithotriptic shock wave generator with truncated ellipsoidal reflector-redistributes acoustic energy density across surface of skin where little or no sensation can be felt
MESTAS J L, CATHIGNOL D, LACRUCHE B, MESTAS J
(US5233980-A) , 1989
-
Focussed ultrasonic wave generator-has gps. of piezoelectric transducers arrayed w.r.t. common focal points, with resonance frequencies in geometrical progression
CATHIGNOT D, LACRUCHE B, MESTAS J L, CATHIGNOL D
(US5015929-A) , 1989
-
Arc discharge control for generation of shock waves-uses high resistance placed between arcing electrodes to produce undamped shock wave in liquids for medical use
CATHIGNOL D, LACRUCHE B, MESTASJL, MESTAS J L
(DE3865545-G) , 1989
-
LIMITATIONS OF EXTRACORPOREAL LITHOTRIPSY FOR BILIARY-TRACT LITHIASIS
PONCHON T, MARTIN X, CHAVAILLON A, BOUSTIERE C, MESTAS JL
GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 13(2BIS) , A235- A235, 1989
-
Spatial light distribution in tumors : Phantom measurements
Lenz P
Med. Phys., 16 , 326, 1989
-
Simulation de lignes échographiques RF pour la validation d'algorithmes de traitement du signal et des systèmes d'émission réception ultrasonores
Martin C., Chapelon JY, Cathignol D
Traitement du Signal, 6(1) , 49- 49, 1989
-
Nuovo approccio per la misura continuata degli STI mediante l'uso associato de l'ECG e della velocita del flusso sanguigno aortico ottenuta con il doppler pulsato
Muchada R, Rinaldi A, Vernier F, Lavandier B, Cathignol D
A.P.I.C.E., 4 , 1989
-
Nuovo approccio per la misura continua degli STI mediante l'uso associato dell'ECG e della velocita del flusso sanguino aortico ottenuta con il doppler pulsato
Muchada R, Rinaldi A, Vernier F, Lavandier B, Cathignol D
A.P.I.C.E., 4 , 65- 75, 1989
-
Détecteur à anse tournante
Mestas JL, Technomed
Brevet(89.04018) , 1989
-
A new transurethral rotating resectoscope
Devonec M, Mestas JL, Perrin P., Cathignol D
- -
1989
-
L'oedème cardiaque au cours de la perfusion hypothermique : apport de l'impédance
Jeannot T., Jossinet J, Larèse A., Marcsek P., Ferrera R.
- -
1989
-
Assessing the vertical sensitivity of plane arrays of electrodes
Jossinet J, Kardous G.
- -
1989
-
A new computerized impedance cardiograph usable for infarction rehabilitation
Jossinet J, Leftheriotis G., Chavrier F., Saumet J.L.
- -
1989
-
Appareil de repérage et de visualisation en temps réel de concrétion
Cathignol D, Lacruche B., Lacoste F
Brevet international N° PCT/FR 89/00432(PCT/FR 89/00432) , 1989
-
Dispositif piézoélectrique à ondes négatives réduites
Cathignol D, Lacruche B., Mestas JL
Brevet réduction par ondes négatives N° 89 07042(89 07042) , 1989
-
Procédé de mesure d'une variation de pression au sein d'un milieu liquide confiné ou circulant, par microsphères explosives
Chapelon JY
Brevet microbulles explosives N° 89 06 392(89 06 392) , 1989
-
Procédé et dispositif pour améliorer la reproductibilité du régime de décharge d'un arc électrique par interposition d'un liquide électriquement conducteur
INSERM, Technomed
Brevet liquide conducteur, N° 89.08846(89.08846 ) , 1989
-
Appareil de repérage et de visualisation en temps réel de concrétion. - Demande Internationale N° PCT/FR 89/00432
Lacruche B., Cathignol D, Lacoste F
Brevet(8900432) , 1989
-
Pseudo-random Noise Doppler Profilmeter using serial Processing
Cathignol D, Travinski Z.
- -
Septembre 19-23 1988
-
RESULTS OF PERITONEO-VENOUS SHUNTING FOR CHRONIC CIRRHOTIC ASCITES
POUYET M, GOUILLAT C, BAULIEUX J, BERARD P, RIVOIRE M, DUCERF C
LYON CHIRURGICAL, 84(5) , 337- 339, 1988
-
RESULTS OF PORTACAVAL SHUNTS FOR CHRONIC CIRRHOTIC ASCITES
POUYET M, BAULIEUX J, BERARD P, GOUILLAT C, DUCERF C, RIVOIRE M
LYON CHIRURGICAL, 84(5) , 343- 345, 1988